SERVICE AND CALIBRATION:
Professionally refurbished, serviced, and calibrated by our qualified in-house biomedical technicians.
Each unit undergoes a comprehensive performance inspection and is prepared for patient use prior to shipment.
Includes:
- 12-Month Warranty
- 12-Month Fit-for-Patient-Use Certificate
- Certified BioMed Equipment Diagnostic Report
- Printed Order Sheet Identifying the ZOLL X Series Advanced and Serial Number of the Unit Shipped
Standard Configuration Includes:
Defibrillation and Therapy
- Manual Defibrillation (up to 200J ZOLL Rectilinear Biphasic™)
- AED Mode
- Real CPR Help® with CPR Dashboard™ (real-time compression depth, rate, and release feedback)
- Noninvasive Transcutaneous Pacing
- Synchronized Cardioversion
- See-Thru CPR® (helps display the underlying ECG rhythm during active chest compressions)
Monitoring and Clinical Support
- 3-Lead and 12-Lead ECG Monitoring
- 12-Lead Interpretive Analysis
- Real BVM Help® Ventilation Feedback
- TBI Dashboard™
- Pulse Oximetry (SpO₂), Masimo
- Noninvasive Blood Pressure (NIBP)
- End-Tidal CO₂ Capnography (EtCO₂), Microstream®
Included With Every Unit:
- 12-Lead ECG Cable
- NIBP Hose
- NIBP Adult Cuff
- SpO₂ Sensor
- SpO₂ Adapter Cable
- Multifunction Therapy Cable
- Adult Multifunction Pads
- Printer Paper
- EtCO₂ Sampling Line
- Battery
- ECG Electrodes
- Carrying Case
Accessories May Be Pre-Owned And Are Inspected, Sanitized And Fully Functional.
Specifications:
| Physical | |
|---|---|
| Weight | 10.6 lb (4.8 kg) without battery and paper / 11.7 lb (5.3 kg) with battery and paper |
| Dimensions (H x W x D) | 8.9 x 10.4 x 7.9 in (22.6 x 26.4 x 20.1 cm) |
| Display | 6.5 in (16.56 cm) diagonal color LCD, 640 x 480 pixels |
| Patient Modes | Adult, Pediatric and Neonate. Patient mode automatically applies configurable defaults for alarm limits, defibrillation energy and NIBP settings |
| Defibrillator | |
| Waveform | ZOLL Rectilinear Biphasic™ |
| Energy Range | 1 to 200 joules with 19 selectable energy settings |
| Charge Time | Less than 7 seconds with a new, fully charged battery |
| Synchronized Cardioversion | Synchronizes the defibrillator pulse to the patient's R wave |
| RapidShock™ | Shock/No Shock decision with device pre-charge in approximately 4 to 5 seconds when used in Adult Mode with authorized ZOLL CPR electrodes |
| Pacer | |
| Type | External transcutaneous, constant-current pacing |
| Modes | Demand and Fixed |
| Rate | 30 to 180 bpm |
| Output Current | 0 to 140 mA |
| Real-Time Clinical Feedback | |
| Real CPR Help® / CPR Dashboard™ | Real-time chest compression depth and rate feedback with release indicator and Perfusion Performance Indicator (PPI) |
| See-Thru CPR® | Filters chest compression artifact to help display the underlying ECG rhythm during CPR |
| Real BVM Help® | Provides real-time ventilation feedback including ventilation rate and tidal volume |
| TBI Dashboard™ | Graphical trending of SpO₂, systolic blood pressure and EtCO₂ to support traumatic brain injury monitoring |
| Monitoring | |
| ECG Leads | Automatic detection of 3-lead, 5-lead and 12-lead ECG cables. Leads I, II, III, aVR, aVL, aVF and V1-V6 |
| Heart Rate Range | 30 to 300 bpm |
| SpO₂ | Masimo® SET. Oxygen saturation range 0 to 100%. Pulse rate range 25 to 240 bpm |
| NIBP | Smartcuf® and Sure BP® technology. Displays systolic, diastolic and mean pressure. Automatic intervals from 1 to 60 minutes plus manual measurements |
| NIBP Pressure Range | Systolic 20 to 260 mmHg, diastolic 10 to 220 mmHg, mean 13 to 230 mmHg |
| EtCO₂ | Microstream® capnography. Measurement range 0 to 150 mmHg with respiration rate from 0 to 149 breaths/min |
| EtCO₂ Response Time | 2.9 seconds typical / 3.9 seconds maximum |
| Printer and Data | |
| Printer | High-resolution thermal printer using 80 mm paper. 25 or 50 mm/sec paper speed. Can print up to 3 waveforms |
| Trend Data | Up to 24 hours of trend data at 1-minute intervals |
| Memory | Stores a combination of 24 hours of trends, up to 500 non-ECG events and 32 monitor, defibrillator, pacer and treatment snapshots |
| Power | |
| Battery | Rechargeable lithium-ion, 11.1 VDC, 6.6 Ah, 73 Wh |
| Run Time (manufacturer specification, with a new, fully charged battery) | At least 7 hours of continuous 3/5-lead ECG monitoring at room temperature, or at least 300 defibrillator discharges at the maximum 200J energy setting. Actual run time depends on battery condition, display settings and device usage. |
| Environmental | |
| Operating Temperature | 32° to 122°F (0° to 50°C) |
| Water / Dust Resistance | IEC 60529 IP5X dust protection and IPX5 water protection |
| Drop Rating | 76.2 cm (30 in) functional drop per EN 1789; tested at 2 metres per IEC 60601-1 |
| Vibration | Tested to EN 1789 ambulance requirements and RTCA/DO-160G helicopter vibration profiles |