Stryker Physio-Control LIFEPAK 15 V4 Monitor/Defibrillator - Refurbished
SERVICE AND CALIBRATION:
Professionally refurbished, serviced, calibrated by our qualified in-house biomedical technicians.
Each unit undergoes a comprehensive performance inspection and is prepared for patient use prior to shipment.
Includes:
- 12-Month Warranty
- 12-Month Fit-for-Patient-Use Certificate
- Certified BioMed Equipment Diagnostic Report
- Printed Order Sheet Identifying the LIFEPAK 15 V4 and Serial Number of the Unit Shipped
Options:
Available in three configurations. Every unit includes the standard configuration below. Choose the standard unit, or add Continuous Temperature Monitoring or Dual-Channel Invasive Blood Pressure (IBP) Monitoring.
- Standard Configuration
- Standard Configuration + Continuous Temperature Monitoring
- Standard Configuration + Dual-Channel Invasive Blood Pressure (IBP) Monitoring
Standard Configuration Includes:
Defibrillation and Therapy
- Manual Defibrillation (up to 360J ADAPTIV Biphasic)
- AED Mode with Shock Advisory System
- Noninvasive Transcutaneous Pacing
- Synchronized Cardioversion
- CPR Metronome (audible coaching tones)
Monitoring
- 3-Lead ECG Monitoring
- 12-Lead ECG Analysis (University of Glasgow Program)
- ST-Segment Trend Tracking (continuous sampling)
- Pulse Oximetry (SpO₂), Masimo SET
- Noninvasive Blood Pressure (NIBP), oscillometric
- End-Tidal CO₂ Capnography (EtCO₂), Microstream side-stream sampling
Custom Configurations:
SpCO and SpMet (Rainbow) monitoring may be available on select units.
Call us for custom configurations and availability.
Included With Every Configuration:
- 12-Lead ECG Cable (trunk + V leads)
- NIBP Hose
- NIBP Adult Cuff
- SpO₂ Sensor
- SpO₂ Adapter Cable
- Multifunction Therapy Cable
- Adult Multifunction Pads
- 100mm Print Paper
- CO₂ Filter Line
- 2 Batteries
- ECG Electrodes
- Carrying Case with Back Pouch and Shoulder Strap
Accessories May Be Pre-Owned And Are Inspected, Sanitized And Fully Functional.
Specifications:
| Physical | |
|---|---|
| Weight | 17.5 lb (7.9 kg) basic unit / 18.5 lb (8.4 kg) fully featured, with roll paper and two batteries installed |
| Dimensions (H x W x D) | 12.5 in x 15.8 in x 9.1 in (31.7 cm x 40.1 cm x 23.1 cm) |
| Display | 8.4 in diagonal color LCD, 640 x 480, backlit. Up to 3 waveforms. Selectable SunVue high-contrast mode |
| Defibrillator | |
| Waveform | Biphasic Truncated Exponential (ADAPTIV) |
| Energy Range (Manual) | 2 to 360 joules (25 selectable settings) |
| Charge Time | Less than 10 seconds to 360J, typical |
| AED Mode | Shock Advisory System. Shocks from 150 to 360J. Ready to shock within 20 seconds of "Shock Advised" |
| Synchronized Cardioversion | Energy delivery within 60 msec of the QRS peak |
| Electrodes | QUIK-COMBO pacing/defibrillation/ECG electrodes, 8 ft (2.4 m) cable |
| Pacer | |
| Mode | Demand or non-demand |
| Rate | 40 to 170 PPM |
| Output Current | 0 to 200 mA |
| Monitoring | |
| ECG Leads | 3-wire cable (3-lead), 5-wire cable (7-lead), 10-wire cable (12-lead) |
| Heart Rate Range | 20 to 300 bpm |
| 12-Lead Analysis | University of Glasgow 12-Lead ECG Analysis Program, includes AMI and STEMI statements |
| SpO₂ | Range 50 to 100%. Accuracy ±2 digits (no motion), ±3 digits (motion). Masimo SET |
| NIBP | Systolic 30 to 255 mmHg, diastolic 15 to 220 mmHg. Accuracy ±5 mmHg. Auto interval 2 to 60 min |
| EtCO₂ | 0 to 99 mmHg. Respiration rate 0 to 99 breaths/min. Warm-up 30 seconds, typical |
| Trends | Up to 8 hours, including automatic ST-segment trending |
| Printer and Data | |
| Printer | 100 mm (3.9 in) thermal strip chart. 25 or 12.5 mm/sec |
| Memory | 360 minutes of continuous ECG or 90 minutes of all channels |
| Reports | Code Summary, 12-Lead ECG, Trend Summary, Vital Sign Summary, Snapshot |
| Communication | Bluetooth and RS232 serial port |
| Power | |
| Batteries | Dual lithium-ion with automatic switching. Each battery weighs 1.3 lb (0.6 kg) or less |
| Run Time (manufacturer specification, with two new, fully charged batteries) | 360 min monitoring, 340 min pacing, or 420 defibrillator discharges at 360J (typical) Actual run time depends on battery condition. |
| Charge Time | 190 minutes, typical |
| External Power | AC or DC adapter. Full operation with or without batteries installed |
| Environmental | |
| Operating Temperature | 32° to 113°F (0° to 45°C) |
| Water/Dust Resistance | IP44 (splash and dust resistant) |
| Drop Rating | 18 in onto a steel surface, 5 drops on each side |
| Vibration | Meets MIL-STD-810E (helicopter, propeller aircraft, ground mobile) |
| Optional Add-Ons | |
| + Continuous Temperature Monitoring | Continuous temperature monitoring. Range 76.6° to 113.4°F (24.8° to 45.2°C). Accuracy ±0.2°C |
| + Dual-Channel Invasive Blood Pressure (IBP) Monitoring | Two invasive blood pressure channels. Range -30 to 300 mmHg. Labels: P1, P2, ART, PA, CVP, ICP, LAP |