{"product_id":"lifepak-cr-plus-replacement-kit-for-charge-pak-2-sets-of-electrodes-copy","title":"LIFEPAK CR Plus Replacement Kit for Charge-Pak","description":"\u003ch2 data-start=\"246\" data-end=\"338\"\u003e\u003cstrong data-start=\"249\" data-end=\"338\"\u003ePhysio-Control LIFEPAK CR Plus \/ EXPRESS AED CHARGE-PAK Kit (Includes Pad \u0026amp; Battery)\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3 data-start=\"340\" data-end=\"360\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp data-start=\"361\" data-end=\"720\"\u003eThe \u003cstrong data-start=\"365\" data-end=\"420\"\u003ePhysio-Control LIFEPAK CR Plus \/ EXPRESS CHARGE-PAK\u003c\/strong\u003e is an OEM replacement kit designed for use with the \u003cstrong data-start=\"473\" data-end=\"492\"\u003eLIFEPAK CR Plus\u003c\/strong\u003e and \u003cstrong data-start=\"497\" data-end=\"516\"\u003eLIFEPAK EXPRESS\u003c\/strong\u003e automated external defibrillators. This all-in-one kit replaces both the \u003cstrong data-start=\"590\" data-end=\"642\"\u003ebattery system and defibrillation electrode pad,\u003c\/strong\u003e which are designed by the manufacturer to be serviced and replaced together.\u003c\/p\u003e\n\u003cp data-start=\"722\" data-end=\"861\"\u003eThe CHARGE-PAK system ensures the AED remains ready for emergency use by providing long-term standby power and preconnected electrode pads.\u003c\/p\u003e\n\u003chr data-start=\"863\" data-end=\"866\"\u003e\n\u003ch3 data-start=\"868\" data-end=\"887\"\u003eWhat’s Included\u003c\/h3\u003e\n\u003cul data-start=\"888\" data-end=\"1131\"\u003e\n\u003cli data-start=\"888\" data-end=\"940\"\u003e\n\u003cp data-start=\"890\" data-end=\"940\"\u003e\u003cstrong data-start=\"890\" data-end=\"940\"\u003e1 × CHARGE-PAK lithium battery \/ charging unit\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"941\" data-end=\"1029\"\u003e\n\u003cp data-start=\"943\" data-end=\"1029\"\u003e\u003cstrong data-start=\"943\" data-end=\"994\"\u003e1 × set of adult defibrillation electrode pads\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1030\" data-end=\"1131\"\u003e\n\u003cp data-start=\"1032\" data-end=\"1131\"\u003e\u003cstrong data-start=\"1032\" data-end=\"1057\"\u003eIntegrated discharger\u003c\/strong\u003e, used to safely deplete a spent CHARGE-PAK prior to disposal or recycling\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cblockquote data-start=\"1133\" data-end=\"1341\"\u003e\n\u003cp data-start=\"1135\" data-end=\"1341\"\u003e\u003cstrong data-start=\"1135\" data-end=\"1149\"\u003eImportant:\u003c\/strong\u003e The battery\/discharger and electrode pads are supplied only as a combined kit and are not available separately. Both components must be replaced at the same time after use or upon expiration.\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003chr data-start=\"1343\" data-end=\"1346\"\u003e\n\u003ch3 data-start=\"1348\" data-end=\"1370\"\u003eKey Specifications\u003c\/h3\u003e\n\u003cul data-start=\"1371\" data-end=\"2018\"\u003e\n\u003cli data-start=\"1371\" data-end=\"1417\"\u003e\n\u003cp data-start=\"1373\" data-end=\"1417\"\u003eBattery Type: \u003cstrong data-start=\"1387\" data-end=\"1417\"\u003eLithium (non-rechargeable)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1418\" data-end=\"1451\"\u003e\n\u003cp data-start=\"1420\" data-end=\"1451\"\u003eStandby Life: \u003cstrong data-start=\"1434\" data-end=\"1451\"\u003eUp to 2 years\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1452\" data-end=\"1579\"\u003e\n\u003cp data-start=\"1454\" data-end=\"1479\"\u003eEnergy Output Capability:\u003c\/p\u003e\n\u003cul data-start=\"1482\" data-end=\"1579\"\u003e\n\u003cli data-start=\"1482\" data-end=\"1532\"\u003e\n\u003cp data-start=\"1484\" data-end=\"1532\"\u003eApproximately \u003cstrong data-start=\"1498\" data-end=\"1526\"\u003e166 shocks at 200 joules\u003c\/strong\u003e, or\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1535\" data-end=\"1579\"\u003e\n\u003cp data-start=\"1537\" data-end=\"1579\"\u003eApproximately \u003cstrong data-start=\"1551\" data-end=\"1579\"\u003e103 shocks at 360 joules\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1580\" data-end=\"1629\"\u003e\n\u003cp data-start=\"1582\" data-end=\"1629\"\u003eEstimated Operating Time: \u003cstrong data-start=\"1608\" data-end=\"1629\"\u003eUp to 800 minutes\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1630\" data-end=\"1731\"\u003e\n\u003cp data-start=\"1632\" data-end=\"1669\"\u003eElectrode Pad Replacement Interval:\u003c\/p\u003e\n\u003cul data-start=\"1672\" data-end=\"1731\"\u003e\n\u003cli data-start=\"1672\" data-end=\"1697\"\u003e\n\u003cp data-start=\"1674\" data-end=\"1697\"\u003eEvery \u003cstrong data-start=\"1680\" data-end=\"1691\"\u003e2 years\u003c\/strong\u003e, or\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1700\" data-end=\"1731\"\u003e\n\u003cp data-start=\"1702\" data-end=\"1731\"\u003eImmediately after patient use\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1732\" data-end=\"1767\"\u003e\n\u003cp data-start=\"1734\" data-end=\"1767\"\u003eOEM Part Number: \u003cstrong data-start=\"1751\" data-end=\"1767\"\u003e11403-000002\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1768\" data-end=\"2018\"\u003e\n\u003cp data-start=\"1770\" data-end=\"2018\"\u003eAlternate \/ Cross-Reference Part Numbers:\u003cbr data-start=\"1811\" data-end=\"1814\"\u003e3200727-002, 3200727-005, 3200731-002, 3200731-003, 3200731-009,\u003cbr data-start=\"1880\" data-end=\"1883\"\u003e3201616-001, 3201616-003,\u003cbr data-start=\"1910\" data-end=\"1913\"\u003e3202176, 3202176-003, 3202176-005, 3202176-006, 3202176-007, 3202176-008, 3202176-010,\u003cbr data-start=\"2001\" data-end=\"2004\"\u003e11403-000001\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2020\" data-end=\"2023\"\u003e\n\u003ch3 data-start=\"2025\" data-end=\"2042\"\u003eCompatibility\u003c\/h3\u003e\n\u003cp data-start=\"2043\" data-end=\"2116\"\u003eThis CHARGE-PAK kit is \u003cstrong data-start=\"2066\" data-end=\"2085\"\u003eonly compatible\u003c\/strong\u003e with the following AED models:\u003c\/p\u003e\n\u003cul data-start=\"2117\" data-end=\"2198\"\u003e\n\u003cli data-start=\"2117\" data-end=\"2157\"\u003e\n\u003cp data-start=\"2119\" data-end=\"2157\"\u003e\u003cstrong data-start=\"2119\" data-end=\"2157\"\u003ePhysio-Control LIFEPAK CR Plus AED\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2158\" data-end=\"2198\"\u003e\n\u003cp data-start=\"2160\" data-end=\"2198\"\u003e\u003cstrong data-start=\"2160\" data-end=\"2198\"\u003ePhysio-Control LIFEPAK EXPRESS AED\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cblockquote data-start=\"2200\" data-end=\"2389\"\u003e\n\u003cp data-start=\"2202\" data-end=\"2389\"\u003eThese AED models have been discontinued by the manufacturer and are no longer available for new purchase. This CHARGE-PAK is intended for continued support of existing devices in service.\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003chr data-start=\"2391\" data-end=\"2394\"\u003e\n\u003ch3 data-start=\"2396\" data-end=\"2439\"\u003eReplacement Overview (General Guidance)\u003c\/h3\u003e\n\u003col data-start=\"2440\" data-end=\"2700\"\u003e\n\u003cli data-start=\"2440\" data-end=\"2484\"\u003e\n\u003cp data-start=\"2443\" data-end=\"2484\"\u003ePlace the AED face up on a flat surface\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2485\" data-end=\"2553\"\u003e\n\u003cp data-start=\"2488\" data-end=\"2553\"\u003eLocate the battery compartment at the lower portion of the unit\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2554\" data-end=\"2592\"\u003e\n\u003cp data-start=\"2557\" data-end=\"2592\"\u003eSlide the existing CHARGE-PAK out\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2593\" data-end=\"2649\"\u003e\n\u003cp data-start=\"2596\" data-end=\"2649\"\u003eAlign the new CHARGE-PAK with the compartment rails\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2650\" data-end=\"2700\"\u003e\n\u003cp data-start=\"2653\" data-end=\"2700\"\u003eInsert until fully seated and locked in place\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp data-start=\"2702\" data-end=\"2787\"\u003e(Always follow manufacturer instructions and facility protocols when servicing AEDs.)\u003c\/p\u003e\n\u003chr data-start=\"2789\" data-end=\"2792\"\u003e\n\u003ch3 data-start=\"2794\" data-end=\"2803\"\u003eNotes\u003c\/h3\u003e\n\u003cul data-start=\"2804\" data-end=\"3024\"\u003e\n\u003cli data-start=\"2804\" data-end=\"2853\"\u003e\n\u003cp data-start=\"2806\" data-end=\"2853\"\u003eThis listing is for the \u003cstrong data-start=\"2830\" data-end=\"2853\"\u003eCHARGE-PAK kit only\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2854\" data-end=\"2879\"\u003e\n\u003cp data-start=\"2856\" data-end=\"2879\"\u003eAED device not included\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2880\" data-end=\"2949\"\u003e\n\u003cp data-start=\"2882\" data-end=\"2949\"\u003eDesigned for emergency response readiness and regulatory compliance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2950\" data-end=\"3024\"\u003e\n\u003cp data-start=\"2952\" data-end=\"3024\"\u003eReplacement of battery and pads simultaneously is required by OEM design\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Physio-Control \/ Stryker","offers":[{"title":"Default Title","offer_id":50995099074866,"sku":"11403-000002","price":499.99,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0055\/4680\/3286\/files\/lifepak-cr-plus-replacement-kit-for-charge-pak-3960928.jpg?v=1774026126","url":"https:\/\/stretchersrus.com\/products\/lifepak-cr-plus-replacement-kit-for-charge-pak-2-sets-of-electrodes-copy","provider":"Stretchers R Us","version":"1.0","type":"link"}